Ohmeda-Trusat-Manual-Lt545382020 Adobe Acrobat Reader DC United StatesDownload Adobe Manual Mens Healthcare Made easy More than a pharmacy Ebook PDF:Manual Wellbeing Our new offering is a holistic. GE Appliances' owner manuals offer use and care guidelines, installation instructions and feature guides. Also find Quick spec literature and Energy guides.

  1. Ge Venue 50 User Manual Pdf Fillable
  2. Ge Venue 50 User Manual Pdf User
  3. Ge Venue 50 User Manual Pdf File
Loading...

Ge Venue 50 User Manual Pdf Fillable

DSXH43EFWW

GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer

Dimensions and Installation Information (in inches)

Exhaust Options: Electric—4-way via rear, right, left

and bottom.

Circuit Requirements: Electric—An individual,

B

properly-grounded branch circuit, protected by a 30-

amp circuit breaker or a time-delay fuse, is required.

Electric Dryer Rating:

120/240V, 3-wire, 5600W, 24A

Electric

120/208V, 3-wire, 4400W, 22A

Connection

Note: Dryer wall outlet must be located within 36”

of service cord entry and accessible when dryer is

mounted in position.

H

Installation Information: For complete information,

I

see installation instructions packed with your dryer.

3/16'

Gas Pipe Connection

REAR VIEW

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.

E

Door Open

F

90°

Optional

Vent Knockout

C

SIDE VIEW

G

Listed by

Underwriters

Laboratories

DSXH43EFWW

Ge venue 50 user manual pdf 2 10

GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer

Dimensions and Installation Information (in inches)

Special Installation Requirements Undercounter Installation

Accessory mounting kits are required for undercounter installation. To order, call 1-800-848-7722.

Stacked Installation: Brackets for stacking dryer over washer are included with the dryer.

Alcove or Closet Installation:If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. The dryer MUST be exhausted to the outdoors. Minimum clearances between dryer cabinet and ­adjacent walls or other surfaces are: 0' either side, 3' front and rear Minimum vertical space from floor to overhead ­cabinets, ceilings, etc. is 52'. Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally

distributed. The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. No other fuel-burning appliance shall be installed in the same closet with the dryer.

Bathroom or Bedroom Installation: The dryer must be exhausted to the outdoors. The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.

Pdf

Minimum Clearances other than Alcove or Closet Installations:

Minimum clearances to combustible surfaces: 0' both sides, 3' rear

Free-Standing Installation

Manual

36'

25-3/4'

53-1/2'

Stacked Installation

70-5/8'

Ge Venue 50 User Manual Pdf User

For answers to your Monogram,® GE Profileor

25-3/4'

26-3/4'

GE® appliance questions, visit our website at

geappliances.com or call GE Answer Center®

service, 800.626.2000.

e

Wid

x3/4'

High

Sides

3/4'

All

on

Lip

Ge Venue 50 User Manual Pdf File

14'

29'

56'-60'

Max.

Undercounter Installation

Countertop

Washer

Top Sheet

Specification Revised 12/09

360426